FLAMEX® PANTO LEAD-FREE 26/45 kV
FLAMEX® PANTO LEAD-FREE 26/45 kV
FLAMEX
MEDIUM VOLTAGE ROOF CABLES
For inside and outside use in railway vehicles. Installation in cable ducts or tubes. Available on request: HV loop, completely pre-assembled flexible cables with plugs and sealing ends, electrically tested.
FLAMEX® PANTO LEAD-FREE 50mm²
Rif. Nexans 79477908
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 50 mm²
- Sezione schermo: 16 mm²
- Diameter over external semi-conductor: 29,0 mm
- Diametro esterno min: 34,0 mm
- Diametro esterno max: 36,0 mm
- Peso approssimativo del cavo: 2100 kg/km
FLAMEX® PANTO LEAD-FREE 95mm²
Rif. Nexans 79477912
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 95 mm²
- Sezione schermo: 16 mm²
- Diameter over external semi-conductor: 32,0 mm
- Diametro esterno min: 40,0 mm
- Diametro esterno max: 42,0 mm
- Peso approssimativo del cavo: 2500 kg/km
FLAMEX® PANTO LEAD-FREE 150mm²
Rif. Nexans 79477916
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 150 mm²
- Sezione schermo: 16 mm²
- Diameter over external semi-conductor: 36,0 mm
- Diametro esterno min: 41,0 mm
- Diametro esterno max: 43,0 mm
- Peso approssimativo del cavo: 3200 kg/km
FLAMEX® PANTO LEAD-FREE 185mm²
Rif. Nexans 79477918
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 185 mm²
- Sezione schermo: 25 mm²
- Diameter over external semi-conductor: 37,0 mm
- Diametro esterno min: 42,0 mm
- Diametro esterno max: 44,0 mm
- Peso approssimativo del cavo: 3600 kg/km
FLAMEX® PANTO LEAD-FREE 240mm²
Rif. Nexans 79477919
- Imballo: Cut to length (m)
- Sezione del conduttore del cavo: 240 mm²
- Sezione schermo: 25 mm²
- Diameter over external semi-conductor: 40,0 mm
- Diametro esterno min: 45,0 mm
- Diametro esterno max: 48,0 mm
- Peso approssimativo del cavo: 4300 kg/km
Descrizione
Descrizione
Norme
-
ProductEN 45545-2 (HL3); EN 50264-1; IEC 60502
DESIGN
1. Conductor: Flexible stranded tinned copper, class 5 acc. to IEC 60228
2. Inner semi-conductive layer: Conductive rubber
3. Insulation: Cross-linked compound type EI 110 acc. to EN 50264-1
4. Outer conductive layer: Conductive rubber easy to strip
5. Screen: Conductive tape + tinned single wires with separator
6. Outer sheath: Cross-linked compound type EM104 acc. to EN 50264-1. Oil, diesel, ozone and UV resistant. Colour: black
Example of cable marking: FLAMEX PANTO – LEAD FREE - 1x [conductor nominal cross section] / [geometrical screen cross-section] 26/45kV I LYNXEO I WEEK/YEAR batch-no
GUIDE TO USE
- Cabling rules are given in EN 50343 and EN 50355
- Bending radius:
- Static use: 5 x outer cable diameter
- For installation and occasional movements: 10 x outer cable diameter
Caratteristiche
Caratteristiche
Caratteristiche costruttive
Caratteristiche costruttive
Caratteristiche elettriche
Caratteristiche elettriche
Caratteristiche d'utilizzo
Caratteristiche d'utilizzo
I nostri siti web
Seleziona il tuo paese per trovare i nostri prodotti e soluzioni
-
Africa
- Africa
- Ghana
- Ivory Coast
- Morocco
- North West Africa
- Americas
- Asia
- Europe
- Oceania